A simultaneous optical and electrical in-vitro neuronal recording system to evaluate microelectrode performance

PLoS One. 2020 Aug 20;15(8):e0237709. doi: 10.1371/journal.pone.0237709. eCollection 2020.

Abstract

Objectives: In this paper, we aim to detail the setup of a high spatio-temporal resolution, electrical recording system utilising planar microelectrode arrays with simultaneous optical imaging suitable for evaluating microelectrode performance with a proposed 'performance factor' metric.

Methods: Techniques that would facilitate low noise electrical recordings were coupled with voltage sensitive dyes and neuronal activity was recorded both electrically via a customised amplification system and optically via a high speed CMOS camera. This technique was applied to characterise microelectrode recording performance of gold and poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) coated electrodes through traditional signal to noise (SNR) calculations as well as the proposed performance factor.

Results: Neuronal activity was simultaneously recorded using both electrical and optical techniques and this activity was confirmed via tetrodotoxin application to inhibit action potential firing. PEDOT/PSS outperformed gold using both measurements, however, the performance factor metric estimated a 3 fold improvement in signal transduction when compared to gold, whereas SNR estimated an 8 fold improvement when compared to gold.

Conclusion: The design and functionality of a system to record from neurons both electrically, through microelectrode arrays, and optically via voltage sensitive dyes was successfully achieved.

Significance: The high spatiotemporal resolution of both electrical and optical methods will allow for an array of applications such as improved detection of subthreshold synaptic events, validation of spike sorting algorithms and a provides a robust evaluation of extracellular microelectrode performance.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Action Potentials / physiology*
  • Algorithms
  • Electrodes, Implanted*
  • Gold / chemistry
  • Humans
  • Microelectrodes*
  • Neurons / physiology*
  • Polymers / chemistry
  • Signal Transduction / physiology

Substances

  • Polymers
  • Gold

Grants and funding

This work was supported by the Auckland Medical Research Foundation [grant number 1114010]; the Marsden Fund Council, Auckland, NZ [grant number UOA1402]; and the Neurological Foundation of New Zealand [grant number 1422-MS]. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.